<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.climasmonterrey.com/blogs/preguntas-recuperacion-y-reciclaje-refrigerante/feed" rel="self" type="application/rss+xml"/><title>Climasmonterrey.com Centro - Blog , (Literatura) Recuperación y Reciclaje Refrigerante</title><description>Climasmonterrey.com Centro - Blog , (Literatura) Recuperación y Reciclaje Refrigerante</description><link>https://www.climasmonterrey.com/blogs/preguntas-recuperacion-y-reciclaje-refrigerante</link><lastBuildDate>Mon, 27 Apr 2026 23:06:18 -0700</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Precauciones al Utilizar Equipo de Recuperación y Reciclado]]></title><link>https://www.climasmonterrey.com/blogs/post/precauciones-al-utilizar-equipo-de-recuperación-y-reciclado</link><description><![CDATA[Todas las máquinas de recuperación vienen con un instructivo o manual de operación, donde aparecen las instrucciones sobre cómo operarlas. Sin embargo ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_vszQvDI_TDuenQE432vHHA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_MqrGGaxQSbeEztVR-Ludmg" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_YfZOh2gnSKSzPtMN87r9pA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_x60Ln7-yTuqjM2KIEcQQVg" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_x60Ln7-yTuqjM2KIEcQQVg"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Precauciones al Utilizar Equipo de Recuperación y Reciclado</span></span></span></h2></div>
<div data-element-id="elm_QvBwsBkxRNSvQohL1qCBIw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Todas las máquinas de recuperación vienen con un instructivo o manual de operación, donde aparecen las instrucciones sobre cómo operarlas. Sin embargo, aportan muy poco acerca de cómo aplicarlas e integrarlas.&nbsp;</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Aplicar una máquina para recuperación y reproceso (R y R) es proceder de manera justa. Sin embargo, la otra opción, recuperar y recargar, debe considerarse muy cuidadosamente.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">El primer punto que debe reconocerse es que los objetivos son:</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">1. Remover el refrigerante en el tiempo más corto posible.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">2. Usar prácticas de servicio para proteger el sistema de contaminación potencial.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La contaminación potencial es con mucho, la parte de la operación más crítica y la más descuidada. La gran amenaza es el riesgo potencial de contaminar el refrigerante de una unidad a otra.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">A menos que se apliquen adecuadamente, el mal uso de los equipos para R y </span><span style="font-size:16px;">R</span><span style="font-size:16px;">&nbsp;puede volverse para la industria de la refrigeración, lo que las agujas hipodérmicas sucias serían a la profesión médica.</span></span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La contaminación cruzada puede ocurrir cada que se hace la recuperación en un sistema, utilizando otro sistema refrigerante y recargándolo con el mismo gas. Sin embargo, utilizando un poco de precaución, el problema puede evitarse.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 18 Sep 2023 14:55:21 -0600</pubDate></item><item><title><![CDATA[Reemplazando el Aceite]]></title><link>https://www.climasmonterrey.com/blogs/post/reemplazando-el-aceite</link><description><![CDATA[La solución es utilizar el mismo refrigerante para reemplazar todo el aceite que se haya removido de un sistema. Recargando totalmente con líquido, se ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_WHqLUOT4S7Cde_RBixLvjA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_Zek0mLV5RBqZKq_9CtEkeQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_2g2L-yy5TAeL93Bu-f4LPA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_78chjNBkRT-ztRR1sXRTWg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Reemplazando el Aceite</span></span></span></h2></div>
<div data-element-id="elm_WL4qwEQCQGaj87_zGCuY6A" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div><span style="color:inherit;font-size:16px;">La solución es utilizar el mismo refrigerante para reemplazar todo el aceite que se haya removido de un sistema. Recargando totalmente con líquido, se puede evitar </span><span style="font-size:16px;">este problema</span><span style="color:inherit;font-size:16px;">&nbsp;del tanque contaminado, usando el mismo refrigerante como un solvente para limpiar el tanque.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Sin embargo, antes de hacerlo, veamos las mejores opciones para hacer esto.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">La manera más segura para cargar con </span><span style="font-size:16px;">líquido</span><span style="color:inherit;font-size:16px;">&nbsp;es con el compresor apagado. Se vuelve entonces importante aprender cómo sacar el mayor provecho del vacío hacia donde se está cargando.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Primero, verifique que el ventilador del evaporador esté apagado, especialmente en una unidad separada (</span><span style="font-size:16px;">Split</span><span style="color:inherit;font-size:16px;">). Si se recarga con el ventilador encendido, todo lo que se hace es forzar calor adicional hacia el sistema, provocando que se evapore más líquido y se llene el sistema con gas, antes de que pueda entrar todo el líquido.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Hay que recordar que si está cargando líquido de su tanque con una manguera solamente, no es bueno dividir en dos mangueras su manifold. En realidad, se pierde algo de habilidad para cargar líquido, puesto que el cambio en volumen de una a dos </span><span style="font-size:16px;">mangueras</span><span style="color:inherit;font-size:16px;">&nbsp;causa que cierta cantidad se evapore, desplazando el volumen del líquido que pudo haber tomado el sistema.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Para mejores resultados, siempre cargue líquido con una sola manguera hacia el condensador.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Ahora viene la parte difícil, cómo cargar líquido hacia un sistema en operación.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La mejor manera es a través del evaporador. Si se toma el tiempo para instalar una válvula de acceso adelante de la válvula del condensador o recibidor, mientras el sistema está abierto y se está reparando, el cargar líquido se vuelve extremadamente rápido y fácil.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Para cargar el líquido restante del tanque, empiece simplemente por cerrar la válvula, y deje que el diferencial de presión succione el líquido y aceite restantes del tanque. El líquido se evaporará completamente al pasar a través del evaporador.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La siguiente opción para cargar líquido a un sistema en operación, es midiéndolo. La manera más segura es comprar un dispositivo de carga de líquido a vapor.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Si cree que puede medirlo usted mismo cerrando ligeramente la válvula, se recomienda que por lo menos se ponga una mirilla en la línea, para verificar que no se está introduciendo líquido hacia el compresor.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Un beneficio adicional al cargar en forma </span><span style="font-size:16px;">líquida</span><span style="color:inherit;font-size:16px;">&nbsp;es que permite purgar completamente los gases no condensables del tanque de recuperación, con menos de un 1% de pérdida.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Para hacer esto, simplemente se instala una mirilla en la línea del tanque, y se purga solamente después de que se ha ido el líquido. Realmente, la mejor manera de purgar los no condensables, es cuando no hay líquido presente.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Purgar el aire que pudiera haber pasado hacia el tanque de recuperación mientras hay líquido presente, es un esfuerzo en vano. La idea de que todo el aire está en la parte </span><span style="font-size:16px;">superior</span><span style="color:inherit;font-size:16px;">&nbsp;es verdad solamente mientras el gas dentro del tanque está estancado. En el momento que se libera la presión al empezar a purgar el tanque, se crea una turbulencia que mezcla el vapor del refrigerante con el aire.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Adicional a este efecto, es el hecho de que la superficie del refrigerante comienza a </span><span style="font-size:16px;">vaporizar,</span><span style="color:inherit;font-size:16px;">&nbsp;debido a la baja de presión. El mito común de que solamente se necesita purgar la parte superior del tanque, mientras se sostiene un detector de fugas frente a él, es ridículo.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Aún la costumbre de comparar temperatura contra </span><span style="font-size:16px;">presión</span><span style="color:inherit;font-size:16px;">&nbsp;es </span><span style="font-size:16px;">riesgosa</span><span style="color:inherit;font-size:16px;">, puesto que está basado en la suposición de que el tanque del refrigerante puede tomar calor adecuadamente, en una proporción lo suficientemente rápida para mantener las lecturas exactas.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Con el nivel de vacíos propuesto por la EPA, la manera más segura para evitar que los no condensables se vuelvan a recargar, es manteniéndolos en el cilindro de recuperación, donde pueden ser tratados después que el líquido se haya ido.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Esto reduce grandemente la pérdida de refrigerante al purgar, puesto que no hay líquido que hierva que cause que se mezcle refrigerante extra con los no condensables al ser purgados.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">La manera final de evitar la contaminación cruzada a través de los </span><span style="font-size:16px;">tanques</span><span style="font-size:16px;">&nbsp;es tener un buen método de mantener los tanques organizados y limpios.</span></span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Cada vez que se remueva refrigerante de un sitio de trabajo, los refrigerantes deben ser consolidados en cilindros retornables con doble válvula, Esto permite recuperar y recargar, puesto que siempre se tiene la seguridad que el tanque en su camioneta está vacío.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La mejor manera para consolidar o vaciar un tanque de recuperación, es por gravedad. Esto permite vaciar el líquido del tanque, y al mismo tiempo, retener una carga de vapor dentro del mismo tanque. Para hacer esto, se debe construir un colgador que permita suspender el tanque de recuperación en forma invertida, por arriba del nivel del cilindro de reproceso.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Enseguida, conecte una manguera sin restricciones en el acceso del tanque de reproceso, marcado &quot;líquido&quot;, y el otro extremo de la manguera al acceso del tanque de recuperación invertido, marcado &quot;vapor&quot;.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Entonces se conecta una segunda manguera sin restricciones, entre el acceso del tanque de reproceso marcado &quot;vapor&quot;, y el acceso del tanque de recuperación invertido, marcado &quot;líquido&quot;. Se purgan las mangueras y se abren todas las válvulas. El líquido drenará hacia el cilindro de reproceso en una proporción de aproximadamente medio kilo por minuto, sacando todo el aceite y contaminantes del cilindro de recuperación. El líquido que sale del cilindro de recuperación </span><span style="font-size:16px;">invertido</span><span style="color:inherit;font-size:16px;">&nbsp;es reemplazado por el vapor que viene de la parte superior del cilindro de reproceso.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La habilidad al recuperar refrigerante y luego recargarlo en la misma unidad, es una pieza importante en el problema de los CFC's.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Sin embargo, reconocer el potencial de los problemas, y establecer luego los procedimientos adecuados para evitarlos, es un buen primer paso en el tratamiento de estos.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:44:51 -0600</pubDate></item><item><title><![CDATA[Problemas de Vibración]]></title><link>https://www.climasmonterrey.com/blogs/post/problemas-de-vibracion</link><description><![CDATA[Otro problema es que, debido a que algunas de estas máquinas son extremadamente ligeras, las vibraciones que generan cuando están trabajando, pueden o ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ogy1NloBQWuQfgydqMnz3g" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_EgUOFsWmRxqjQFNWW9oBiQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_ntZlgqKET-eqIU3B-fWJqQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_PzcgnaH-SIGamSzhC58TkQ" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_PzcgnaH-SIGamSzhC58TkQ"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Problemas de Vibración</span></span></span></h2></div>
<div data-element-id="elm_8B7D4kWURS2-NqP-P-jVmw" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_8B7D4kWURS2-NqP-P-jVmw"].zpelem-text{ border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Otro problema es que, debido a que algunas de estas máquinas son extremadamente ligeras, las vibraciones que generan cuando están trabajando, pueden ocasionar fugas excesivas, puesto que no hay suficiente masa para abatir esa vibración.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Tales fugas, pueden provocar que cantidades excesivas de no condensables, sean atraídas con los contaminantes.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La contaminación también puede extenderse a otros sistemas a partir de los tanques de recuperación. Los peores casos ocurrirán durante la recarga, desde tanques llenados por máquinas que sólo recuperan, ajustadas para desplazar primero líquido directamente hacia el tanque.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">Es importante darse cuenta </span><span style="font-size:16px;">de que</span><span style="color:inherit;font-size:16px;">&nbsp;este líquido contiene aceite, directamente del sistema al que se le está dando servicio; aceite que contiene una muestra de los contaminantes que pueda haber en el sistema.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">El uso de pre-filtros ayudará de alguna manera. Pero es necesario darse cuenta </span><span style="font-size:16px;">de&nbsp;que,</span><span style="color:inherit;font-size:16px;">&nbsp;con filtros de pasos múltiples, una sola pasada no removerá todos los contaminantes, y conforme se vaya saturando el filtro, se volverá menos eficiente.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">El peor escenario es, cuando el técnico que recupera de un </span><span style="font-size:16px;">sistema</span><span style="color:inherit;font-size:16px;">&nbsp;hace la reparación necesaria, hace vacío al sistema, y entonces, después de dejar que la mitad de la carga sea transferida al sistema, utilizando el mismo vacío, arranca la unidad y recarga por el lado de baja usando vapor.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">¿Es ésta la manera correcta de hacerlo? No.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Era la manera correcta cuando se usaba refrigerante nuevo para recargar el sistema. Esto no se aplica al refrigerante recuperado que contiene aceite.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">El problema es que cuando se carga vapor de un tanque de recuperación, en el tanque se queda el aceite y todo lo que éste contiene. La primera vez que se usa un tanque, no habrá problema, pero la segunda vez, sí lo habrá.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">El refrigerante líquido que entre al tanque del siguiente sistema a que se le vaya a dar servicio, se mezclará ahora completamente con el aceite y con todo lo que éste contiene, más lo que haya quedado en el tanque de la primera recuperación.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Ahora, cuando se cargue el líquido recuperado hacia el sistema reparado, parte de esta mezcla de aceite es arrastrada con el líquido hacia el sistema.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">Cuando se vaya a cargar en vapor desde el tanque, la parte </span><span style="font-size:16px;">restante de</span><span style="font-size:16px;">&nbsp;</span><span style="font-size:16px;">esta</span><span style="font-size:16px;">&nbsp;nueva </span><span style="font-size:16px;">mezcla</span><span style="font-size:16px;">&nbsp;se quedará en</span></span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">espera de la siguiente carga de refrigerante que sea recuperado. Es difícil encontrar un mejor ejemplo de&nbsp;</span><span style="font-size:16px;color:inherit;">contaminación cruzada.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:43:53 -0600</pubDate></item><item><title><![CDATA[Sobreviviendo a las Reprocesadoras]]></title><link>https://www.climasmonterrey.com/blogs/post/sobreviviendo-a-las-reprocesadoras</link><description><![CDATA[Algunas de las máquinas reprocesadoras son bastante buenas, no hay razón para dudar de su funcionamiento. Sin embargo, no todas han sobrevivido a sus ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_54BMR9vRTTiHcLNu3iniCg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_CBij_k1oQOy3HifRNKJDdQ" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_XluGWJZeS3W228M4xZDOJg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_uDY-ebrMR3mdj0gHcsSAQg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Sobreviviendo a las Reprocesadoras</span></span></span></h2></div>
<div data-element-id="elm_r_dZZ9yPTuetnY9BepXa0g" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Algunas de las máquinas reprocesadoras son bastante buenas, no hay razón para dudar de su funcionamiento. Sin embargo, no todas han sobrevivido a sus reprocesos. Su potencial para acarrear o generar contaminantes surge de cuatro situaciones diferentes:</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">1. Debido a las altas relaciones de compresión y a las temperaturas generadas por los refrigerantes de alta presión, como el HCFC-22. Los separadores de aceite de retorno sobre los cuales dependen algunas </span><span style="font-size:16px;">máquinas</span><span style="color:inherit;font-size:16px;">&nbsp;pueden fallar, y dejar pasar vapor de aceite caliente hacia el tanque. Para revisar su máquina, simplemente purgue algo de los no condensables del tanque inmediatamente después de la recuperación, poniendo al mismo tiempo un trapo frente a la válvula de purga. Si el separador de</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">aceite ha trabajado bien, no quedará señal de aceite. En este caso, deberá inspeccionarse rutinariamente el nivel de aceite en el compresor, para asegurarse que no esté bajo. El nivel bajo de aceite acorta la vida útil de la unidad, y puede causar calor excesivo.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:inherit;font-size:16px;">2. Puesto que una máquina de R y </span><span style="font-size:16px;">R</span><span style="color:inherit;font-size:16px;">&nbsp;es por naturaleza un sistema de refrigeración, tiene el potencial de generar sus propios ácidos. Debido al desgaste que se genera en el compresor de la máquina de R y R, pueden romperse los devanados y también formarse ácido dentro del mismo compresor. La mayor parte del destilado o de la separación de aceite ocurren antes de llegar a este punto; así que, cualquier contaminante generado por el dispositivo puede pasar al tanque, y entonces recargarse a la unidad. Esto puede controlarse mediante una bitácora de mantenimiento estricta, donde el aceite sea cambiado consistentemente.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">3. Las máquinas de recuperación también pueden producir contaminantes cruzados, a partir de los vacíos que habitualmente propone la EPA (Agencia de Protección Ambiental). Debido a las muchas uniones mecánicas y vibraciones a las que están expuestas las máquinas de R y R, existe la posibilidad de fugas. Esto succionará humedad y aire, afectando directamente la pureza del aceite dentro del compresor de la máquina, dando como resultado una potencial contaminación en el tanque.</span></div><div><span style="color:rgb(11, 32, 45);"><span style="font-size:16px;">El lado de baja de la </span><span style="font-size:16px;">máquina</span><span style="font-size:16px;">&nbsp;nunca deberá trabajarse en vacío. Siempre deberá desviarse una carga positiva de refrigerante del lado de alta hacia el lado de baja, para evitar que entre aire al sistema de recuperación. Durante el mantenimiento, la máquina deberá probarse contra fugas.</span></span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">4. La máquina de R y R tiene el más alto potencial para la contaminación cruzada, a menos que se le dé mantenimiento regularmente. Los filtros completamente cargados, se derramarán al cambiar las temperaturas alrededor de los mismos.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; .</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Cuando se trate de filtros, vaya a la segura. &nbsp;Debe evaluar un cambio de filtro y de aceite con cada servicio.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Aunque no se requiera, por lo menos lo protege.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:42:49 -0600</pubDate></item><item><title><![CDATA[Mezcla de gases diferentes]]></title><link>https://www.climasmonterrey.com/blogs/post/mezcla-de-gases-diferentes</link><description><![CDATA[En el primer tipo de contaminación, la mezcla de refrigerantes, la manera más fácil de evitar esto es utilizando máquinas designadas (una para cada re ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_kI7QnLkgRQiS5he4ZvvgmA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_LnEOsuIjQy23PrL6bNIb-w" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_lH585J5ITAO-t7u_ZGfF2Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_TvXweMqkRGeM18ZclWYAlA" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Mezcla de Gases Diferentes</span></span></span></h2></div>
<div data-element-id="elm_07nQ49QMSwKqzvSJAraCwA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">En el primer tipo de contaminación, la mezcla de refrigerantes, la manera más fácil de evitar esto es utilizando máquinas designadas (una para cada refrigerante).</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Desafortunadamente, esto no siempre es posible. Si se va a utilizar la misma máquina sobre diferentes gases, se debe asegurar de que haya sido cuidadosamente limpiada, antes de usarla con un nuevo gas.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">La mejor manera es cambiar el aceite (y filtros) antes de seguir adelante con otro gas.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Algunos fabricantes dicen que solamente se requiere hacer vacío antes de recuperar un gas diferente. Pero, si se hace esto, se recomienda que el vacío sea profundo y prolongado; ya que un vacío rápido, no necesariamente remueve todo el refrigerante disuelto en el aceite.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">El otro tipo de contaminación cruzada, la introducción de </span><span style="font-size:16px;">contaminantes</span><span style="font-size:16px;">&nbsp;es por mucho la peor de las dos, puesto que los ácidos pueden &quot;crecer&quot; dentro del sistema. La fuente de contaminantes más </span><span style="font-size:16px;">obvia</span><span style="font-size:16px;">&nbsp;es la misma máquina de R y R. El lugar donde con más frecuencia puede ocurrir la contaminación, es en los tanques de recuperación, los cuales almacenan el gas mientras se hace la reparación.</span></span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:41:16 -0600</pubDate></item><item><title><![CDATA[¿Cómo nos ayudan los filtros?]]></title><link>https://www.climasmonterrey.com/blogs/post/como-nos-ayudan-los-filtros</link><description><![CDATA[La práctica de instalar filtros en cada sistema que se abra ayudará a evitar algo de contaminación. Pero la mejor defensa es reconocer cómo se puede p ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_oN4KjsI5SgCYnbr9oqN7OQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_UTCZtE0mSoOoDnQebbypJg" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_KM3xNiJkSuSlm9CUfTuMeQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_hOJAm_bMSBuU8PtDXoFwMA" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Los Filtros Ayudan</span></span></span></h2></div>
<div data-element-id="elm_s0dGWenvSfOWKo-4jB6lDw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><div style="font-size:13px;">La práctica de instalar filtros en cada sistema que se abra ayudará a evitar algo de contaminación. Pero la mejor defensa es reconocer cómo se puede propagar la contaminación, y cómo detenerla antes que suceda.&nbsp;</div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;">En las máquinas de R y R pueden ocurrir dos tipos de contaminación cruzada.</div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;">1. La mezcla de refrigerantes, lo cual puede ocurrir cuando un equipo de recuperación se usa con dos diferentes refrigerantes, sin una limpieza o preparación adecuada.</div><div style="font-size:13px;">2. La introducción de ácidos u otros contaminantes al sistema. Esto puede originarse de un sistema diferente, de la misma máquina de R y R, o de sus tanques que actúan como campos de cultivo.</div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;">En ambos casos, el culpable principal en la contaminación cruzada es el aceite para refrigeración; ya sea el utilizado</div><div style="font-size:13px;">en la máquina de R y R, o el que deja en el tanque el refrigerante recuperado.</div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;">El problema y la solución yacen en la afinidad del aceite hacia los refrigerantes. A temperaturas normales, la única manera de separar el aceite es evaporando el refrigerante, y dejar el aceite y todo lo que pueda estar acarreando. También, el refrigerante es un solvente perfecto que acarrea el aceite de un lugar a otro.</div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:39:34 -0600</pubDate></item><item><title><![CDATA[Aire acondicionado automotriz]]></title><link>https://www.climasmonterrey.com/blogs/post/aire-acondicionado-automotriz</link><description><![CDATA[La sección 609 de la Ley para un Aire Puro de los Estados Unidos, establece los requerimientos con respecto a los acondicionadores de aire automotriz. ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_qI6NnZFGRr6R6QjusBsvSQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_ZJ95-XvJRWS2sBWSRmSGIg" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_SubJuJdYQtaf43WQ6o-cwQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_qgwUWA1OQvGuuIfs_1Z3gQ" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Aire Acondicionado Automotriz</span></span></span></h2></div>
<div data-element-id="elm_as092LoATbWysOK6Cb5pMw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><div style="font-size:13px;"><span style="font-size:16px;">La sección 609 de la Ley para un Aire Puro de los Estados Unidos, establece los requerimientos con respecto a los acondicionadores de aire automotriz. Esta ley estableció que a partir del 1 de enero de 1992, ninguna persona que repare o dé servicio a vehículos automotores, podrá dar servicio a equipos de aire acondicionado automotriz, sin el uso adecuado de equipo aprobado para el reciclado de gas refrigerante.</span></div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;"><span style="font-size:16px;">Asimismo, ninguna persona podrá realizar tal servicio, a menos que haya sido adecuadamente entrenado y certificado para hacerlo. Para establecimientos que demuestren que realizaron tales servicios en menos de 100 vehículos en 1990, dicho requerimiento se hizo efectivo hasta el 1 de enero de 1993.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:35:10 -0600</pubDate></item><item><title><![CDATA[Normas de Seguridad para los CFC's]]></title><link>https://www.climasmonterrey.com/blogs/post/normas-de-seguridad-para-los-cfc-s</link><description><![CDATA[Comúnmente, diferentes organizaciones ofrecen talleres para lograr un mejor entendimiento de los requerimientos sobre la recuperación y reproceso de l ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_3Qx6uh1ERPW554bi4bXleQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_FEPLLW4QS_moCaJ6mf6bUw" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_ja4a7s4YTje4yC5btNB93Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_StNKND1GRV-lUGeQ6eoqNg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Normas de Seguridad para la Recuperación/Reciclado/Reproceso de los CFC's</span></span></span></h2></div>
<div data-element-id="elm_gj4Z9Wf5Su-rsEDeInAQ4A" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div><span style="color:rgb(1, 58, 81);"><span style="font-size:16px;">Comúnmente, diferentes organizaciones ofrecen talleres para lograr un mejor entendimiento de los requerimientos sobre la recuperación y reproceso de los CFC's, tal como lo establecen los reglamentos de la EPA. Los mayores tópicos que se abarcan son el manejo, almacenamiento, transportación, procedimientos y equipos de recuperación, reglamentaciones para el almacenamiento y manejo de desechos peligrosos. También, es esencial que el técnico de servicio tenga un completo entendimiento, sobre la seguridad que involucra el manejo y almacenamiento de los refrigerantes. También se ofrecen programas de certificación aprobados por la EPA. Otras áreas que cubren la mayoría de estos cursos de </span><span style="font-size:16px;">capacitación</span><span style="font-size:16px;">&nbsp;son los procedimientos para la remoción, pruebas básicas en el campo sobre la pureza de refrigerantes, aislamiento de los componentes del sistema para evitar que se escape</span></span></div><div style="font-size:13px;"><span style="font-size:16px;color:rgb(1, 58, 81);">el refrigerante, detección, aislamiento y reparación de fugas.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Es responsabilidad del técnico seguir los procedimientos de las prácticas de seguridad. Esto incluye el reemplazo de los filtros deshidratadores de líquido y succión. Si el sistema sólo tiene uno, instale otro en el lado opuesto. Esto ayudará al proceso de purificación del refrigerante. Los refrigerantes reciclados siguen una norma establecida por ARI (Air Conditioning and Refrigeration Institute), la norma ARI - 700.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:34:06 -0600</pubDate></item><item><title><![CDATA[¿Cuál es el procedimiento para el reproceso del refrigerante?]]></title><link>https://www.climasmonterrey.com/blogs/post/cual-es-el-procedimiento-para-el-reproceso-del-refrigerante</link><description><![CDATA[Como se definió anteriormente, reprocesar un refrigerante, es llevarlo a las especificaciones originales de producción, verificándolo mediante análisi ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_t2jrp15HQEeVxJQnVyJvwA" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_-tJ9oA6zT3irD26luPVSvw" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_vEEdIt5PRBaPUpiqc4D6cQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_aTA6Ew1ORzGpgNE2vWc6Rg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Procedimiento para el Reproceso del Refrigerante</span></span></span></h2></div>
<div data-element-id="elm_vvEsOI1NQgumfjXgRve9pg" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div><span style="color:inherit;font-size:16px;">Como se definió anteriormente, reprocesar un refrigerante, es llevarlo a las especificaciones originales de producción, verificándolo mediante análisis químicos. Para poder llevar esto a cabo, </span><span style="font-size:16px;">esta</span><span style="color:inherit;font-size:16px;">&nbsp;máquina debe cumplir con las normas SAE y remover 100% la humedad y partículas de aceite. Muchas máquinas de recuperación / reciclado, no pueden garantizar que el refrigerante será restaurado a sus especificaciones originales.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Una estación de reciclado para el sitio de trabajo, deberá ser capaz de remover el aceite, ácido, humedad, contami-</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">nantes sólidos y aire, para poder limpiar el refrigerante utilizado.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Este tipo de unidades las hay disponibles para usarse con refrigerantes R-12, R-22, R-500 y R-502, y están diseñadas para el uso continuo que requiere un procedimiento prolongado de recuperación / reciclado.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Este tipo de sistema puede describirse mejor como sigue:</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">1. El refrigerante es aceptado en el sistema, ya sea como vapor o líquido.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">2. El refrigerante hierve violentamente a una temperatura alta, y bajo una presión extremadamente alta.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">3. El refrigerante entra entonces a una cámara separadora grande única, donde la velocidad es reducida radicalmente. Esto permite que el vapor a alta temperatura suba. Durante esta fase, los contaminantes tales como las partículas de cobre, carbón, aceite, ácido y todos los demás, caen al fondo del separador para ser removidos durante la operación de &quot;salida del aceite&quot;.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">4. El vapor destilado pasa al condensador enfriado por aire, donde es convertido a líquido.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">5. El líquido pasa hacia la cámara de almacenamiento. Dentro de la cámara, un ensamble de evaporador disminuye la temperatura del líquido, de aproximadamente 38°C, a una temperatura subenfriada de entre 3° y 4°C.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">6. En este circuito, un filtro deshidratador recargable remueve la humedad, al mismo tiempo que continúa el proceso de limpieza para remover los contaminantes microscópicos.</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">7. Enfriar el refrigerante también facilita transferirlo a cualquier cilindro externo, aunque esté a la temperatura</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">ambiente.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Muchos fabricantes de refrigerante y otros, han dispuesto servicios de recuperación / reproceso de refrigerante, que ofrece a los técnicos de recuperación y aire acondicionado, una forma de deshacerse del refrigerante usado y obtener reemplazos puros como los necesiten. El técnico de servicio debe usar cilindros retornables aprobados, con etiquetas adecuadas. Los cilindros normales son de una capacidad aproximada de 45 kg. de refrigerante usado y aceite, aunque otros contenedores andarán en el rango de 18 kg hasta 1 tonelada.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">La máquina de aire comprimido de desplazamiento </span><span style="font-size:16px;">positivo</span><span style="font-size:16px;">&nbsp;remueve tanto líquido como vapor. El refrigerante es reprocesado a las especificaciones de pureza designadas.</span></span></div><div style="font-size:13px;"><span style="color:rgb(11, 35, 45);">&nbsp;</span></div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">En instalaciones comerciales de gran tamaño, al técnico de servicio se le proporcionan cilindros muestra que son regresados a un centro de reproceso. Esto es a fin de obtener análisis de contaminantes de refrigerante, antes de su evacuación.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Una vez aprobado para reprocesarlo, el refrigerante es removido. Los técnicos llevan entonces el refrigerante al centro de servicio, donde es embarcado a la compañía y procesado de conformidad, para regresarlo para venta futura como refrigerante usado. El reproceso puede utilizarse para refrigerantes de baja (R-11 y R-113) y de alta presión (R-12, R-22, R-114, R-500 Y R-502).</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Las normas de cada compañía varían con respecto al tipo de recipiente usado, para transportar el refrigerante del área de servicio al fabricante. Algunos aceptan cantidades mínimas de 200 lts, 38 lts, etc. Cada fabricante tiene su propio procedimiento, mismo que debe seguirse, y cada compañía requiere de cierto número de documentos.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">Las compañías de reproceso también proporcionan &nbsp;soluciones para el desecho de refrigerantes no deseados.</span></div><div style="color:inherit;font-size:13px;">&nbsp;</div><div style="color:inherit;font-size:13px;"><span style="font-size:16px;">El desecho de refrigerantes sólo se puede llevar a cabo por incineración a 650°C. Actualmente existen aproximadamente 5 plantas en los Estados Unidos, que pueden realizar esto.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:32:27 -0600</pubDate></item><item><title><![CDATA[¿Qué es un Equipo para Reciclar Refrigerante?]]></title><link>https://www.climasmonterrey.com/blogs/post/que-es-un-equipo-para-reciclar-refrigerante</link><description><![CDATA[En el pasado, para hacerle servicio a un sistema, lo típico era descargar el refrigerante a la atmósfera. Ahora, el refrigerante puede ser recuperado ]]></description><content:encoded><![CDATA[
<div class="zpcontent-container blogpost-container "><div data-element-id="elm_7810T3b-SLKHsHJDD0orUQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer"><div data-element-id="elm_7qH5YFL2QYScm7GDr6HlJA" data-element-type="row" class="zprow zpalign-items- zpjustify-content- "><style type="text/css"></style><div data-element-id="elm_V3_twCsrS329FlRonQvX6Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_0eds38jhQ667G41BzcUpAg" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="color:inherit;"><span style="font-weight:600;font-size:13px;"><span style="font-size:20px;">Equipo para Reciclar Refrigerante</span></span></span></h2></div>
<div data-element-id="elm_-RSA6WYmSMafMPZq0eBUuA" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center " data-editor="true"><div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">En el pasado, para hacerle servicio a un sistema, lo típico era descargar el refrigerante a la atmósfera. Ahora, el refrigerante puede ser recuperado y reciclado mediante el uso de tecnología moderna. Sin embargo, los clorofluorocarbonos viejos o </span><span style="font-size:16px;">dañados</span><span style="font-size:16px;">&nbsp;no pueden ser reutilizados simplemente por el hecho de removerlos de un sistema y comprimirlos. El vapor, para ser reutilizado, debe estar limpio. Las máquinas de recuperación /reciclado, como la que aparece en la figura 9.7, están diseñadas para recuperar y limpiar el refrigerante en el sitio de trabajo o en el taller de servicio. El reciclado como se realiza por la mayoría de las máquinas en el mercado </span><span style="font-size:16px;">actualmente</span><span style="font-size:16px;">&nbsp;reduce los contaminantes a través de la separación del</span></span></div><div style="font-size:13px;"><span style="font-size:16px;color:rgb(11, 35, 45);">aceite y la filtración. Esto limpia el refrigerante, pero no necesariamente a las especificaciones de pureza originales del fabricante. El equipo que se muestra en la figura 9.7, es un sistema capaz de manejar los refrigerantes R-12, R-22, R-500 y R-502.</span></div><div style="font-size:13px;"><span style="color:rgb(11, 35, 45);">&nbsp;</span></div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">Muchas de estas unidades, conocidas como unidades de transferencias de refrigerante, están diseñadas para evacuar el sistema. Esto proporciona una máquina recicladora, capaz de regresar los refrigerantes reciclados a un mismo sistema. Algunas unidades tienen equipo para separar el aceite y el ácido, y para medir la cantidad de aceite en el vapor. El refrigerante usado puede reciclarse mediante la máquina recicladora, utilizando filtros deshidratadores recargables de piedras, y otros dispositivos que reduzcan la humedad, partículas, acidez, etc. La separación de aceite del refrigerante </span><span style="font-size:16px;">usado</span><span style="font-size:16px;">&nbsp;se lleva a cabo circulándolo una o varias veces a través de la unidad. La máquina recicladora de un solo </span><span style="font-size:16px;">paso</span><span style="font-size:16px;">&nbsp;procesa el refrigerante a través de un filtro deshidratador o mediante el proceso de destilación. Lo pasa sólo una vez por el proceso de reciclado a través de la máquina, para luego transferirlo al cilindro de almacenamiento. La máquina de pasos múlti-</span></span></div><div style="font-size:13px;"><span style="font-size:16px;color:rgb(11, 35, 45);">ples, recircula varias veces el refrigerante a través del filtro deshidratador. Después de un período de tiempo determinado, o un cierto número de ciclos, el refrigerante es transferido hacia el cilindro de almacenamiento.</span></div><div style="font-size:13px;"><span style="color:rgb(11, 35, 45);">&nbsp;</span></div><div><span style="color:rgb(11, 35, 45);"><span style="font-size:16px;">La unidad que se muestra en la figura 9.7, es una unidad portátil, pesa aproximadamente 39 kilos, y tiene una capacidad de almacenamiento interna de 3.6 kg. Su capacidad de almacenamiento externo es ilimitada. Opera como una unidad de recuperación / reciclado, y cuenta </span><span style="font-size:16px;">con un</span><span style="font-size:16px;">&nbsp;compresor de 1/2 caballo. Su capacidad de recuperación es de aproximadamente 900 g/min. de cualquiera de los refrigerantes.</span></span></div><div style="color:inherit;font-size:13px;">&nbsp;</div></div></div>
</div><div data-element-id="elm_PR4VUyK-GTtSKZMykxQGlg" data-element-type="image" class="zpelement zpelem-image "><style> @media (min-width: 992px) { [data-element-id="elm_PR4VUyK-GTtSKZMykxQGlg"] .zpimage-container figure img { width: 316px !important ; height: 252px !important ; } } @media (max-width: 991px) and (min-width: 768px) { [data-element-id="elm_PR4VUyK-GTtSKZMykxQGlg"] .zpimage-container figure img { width:316px ; height:252px ; } } @media (max-width: 767px) { [data-element-id="elm_PR4VUyK-GTtSKZMykxQGlg"] .zpimage-container figure img { width:316px ; height:252px ; } } [data-element-id="elm_PR4VUyK-GTtSKZMykxQGlg"].zpelem-image { border-radius:1px; } </style><div data-caption-color="" data-size-tablet="" data-size-mobile="" data-align="left" data-tablet-image-separate="false" data-mobile-image-separate="false" class="zpimage-container zpimage-align-left zpimage-size-original zpimage-tablet-fallback-original zpimage-mobile-fallback-original hb-lightbox " data-lightbox-options="
                type:fullscreen,
                theme:dark"><figure role="none" class="zpimage-data-ref"><a class="zpimage-anchor" style="cursor:pointer;" href="javascript:;"><picture><img class="zpimage zpimage-style-none zpimage-space-none " src='https://cdn1.zohoecommerce.com/Imagenes%20Categorias/Fig-9-7.jpg?storefront_domain=www.climasmonterrey.com' width="316" height="252" loading="lazy" size="original" alt="" data-lightbox="true"/></picture></a></figure></div>
</div><div data-element-id="elm_EbQT-GELnntDBVcJWkLnIg" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_EbQT-GELnntDBVcJWkLnIg"].zpelem-text{ border-radius:1px; } </style><div class="zptext zptext-align-left " data-editor="true"><div style="color:inherit;"><div style="font-size:13px;"><span style="font-size:16px;">En la parte del frente, tiene los manómetros de alta y baja presión, así como los puertos de acceso, válvulas, interruptores, selectores, luces indicadoras y el indicador de líquido y humedad. En la parte baja tienen los filtros deshidratadores.</span></div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;"><span style="font-size:16px;">En algunos equipos se puede recuperar refrigerante por ambos lados, baja y alta, al mismo tiempo. Este procedi- miento evita restricciones a través de la válvula de expansión o tubo capilar. Si el técnico recupera solamente por uno de los lados, el resultado puede ser un tiempo excesivo de recuperación o una recuperación incompleta. Por lo tanto, las mangueras se conectan a los lados de alta y baja del sistema de recuperación, y luego a través del lado de alta y baja del sistema de refrigeración. Por ningún motivo deberá removerse líquido del sistema en forma contínua. La unidad está diseñada para recuperar vapor.</span></div><div style="font-size:13px;"><span style="font-size:16px;">La recuperación inicial de refrigerante del lado de alta presión, será de aproximadamente 200 psig.</span></div><div style="font-size:13px;">&nbsp;</div><div style="font-size:13px;"><span style="font-size:16px;">Al operar la unidad y llevar a cabo la recuperación de vapor, se alcanzará un punto cuando se haya completado la recuperación, lo cual será indicado al encenderse una lámpara.</span></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 12 Sep 2023 10:29:29 -0600</pubDate></item></channel></rss>